3. HYDRAULIC POWER UNIT
a. Unit Mounting
CAUTIONS
THE HYDRAULIC POWER UNIT MUST BE LOCATED SO THAT:
C THE DOOR ON THE PUMP ENCLOSURE MUST OPEN/CLOSE FREELY WITH
NO OBSTRUCTIONS.
C THE MANUAL PUMP HANDLE MUST BE ACCESSIBLE AND OPERABLE.
C THE OPERATOR HAS AN UNOBSTRUCTED VIEW OF THE PLATFORM
SURFACE WHILE OPERATING THE MANUAL BACK-UP SYSTEM.
C The design capacity of the bracketry used to mount the hydraulic power unit must meet
the criteria listed in Table [2-2]. These criteria will ensure that the pump mounting will
withstand loads applied during manual pump operation.
TABLE [2-2]: HYDRAULIC POWER UNIT BRACKET LOAD CAPACITIES
LOADING DIRECTION BRACKET CAPACITY
Vertical 125 lbs
Longitudinal (perpendicular to vehicle drive axles) 200 lbs
Lateral (parallel to vehicle drive axles) 100 lbs
END OF TABLE
b. Unit-to-Cylinder Connection
1. Connect the main hydraulic hose to the hydraulic power unit if not already done.
2. Operate the manual backup pump until hydraulic fluid flows out of the open end of the
main hydraulic hose.
3. Lower the platform to ground level.
4. Remove the plug on the top of the hydraulic pump tank. Make sure that the hydraulic
fluid in the tank is at the FULL level. Fill only with Texaco No. 15 aircraft hydraulic fluid
(or equivalent U.S. mil spec H5606E/F oil) and reinstall the plug.